Filter and Regulator Combination Unit Series. This modular type unit offers a rich variety of combinations and features easy maintenance.
Specifications
Type test: Air Filter w/ Auto Drain
Bowl Capacity: 1 US oz. (30cc)
Filtration Rating: 5 micrometer
Flow Rate: 10.6 SCFM (300 L/min ANR)
Fluid Admitted: Air
Min. Pressure Range at 21ºC: 21.8 psi (0.15 MPa)
Proof Pressure: 218 psi (1.5 MPa)
Service Pressure Range at 20ºC: 0~150 psi (0~1MPa)
Service Temperature Range: 41~140ºF (5~60ºC)
Type test: Air Filter w/ Manual Drain
Bowl Capacity: 1 US oz. (30cc)
Filtration Rating: 5 micrometer
Flow Rate: 10.6 SCFM (300 L/min ANR)
Fluid Admitted: Air
Min. Pressure Range at 21ºC: 7.3 psi (0.05 MPa)
Proof Pressure: 218 psi (1.5 MPa)
Service Pressure Range at 20ºC: 0~150 psi (0~1MPa)
Service Temperature Range: 41~140ºF (5~60ºC)
Type test: Micromist Filter w/ Auto Drain
Bowl Capacity: 1 US oz. (30cc)
Filtration Rating: 0.01 micrometer
Flow Rate: 10.6 SCFM (300 L/min ANR)
Fluid Admitted: Air
Min. Pressure Range at 21ºC: 21.8 psi (0.15 MPa)
Proof Pressure: 218 psi (1.5 MPa)
Service Pressure Range at 20ºC: 0~150 psi (0~1MPa)
Service Temperature Range: 41~140ºF (5~60ºC)
Type test: Micromist Filter w/ Manual Drain
Bowl Capacity: 1 US oz. (30cc)
Filtration Rating: 0.01 micrometer
Flow Rate: 10.6 SCFM (300 L/min ANR)
Fluid Admitted: Air
Min. Pressure Range at 21ºC: 7.3 psi (0.05 MPa)
Proof Pressure: 218 psi (1.5 MPa)
Service Pressure Range at 20ºC: 0~150 psi (0~1MPa)
Service Temperature Range: 41~140ºF (5~60ºC)
Type test: Mist Filter w/ Auto Drain
Bowl Capacity: 1 US oz. (30cc)
Filtration Rating: 0.3 micrometer
Flow Rate: 10.6 SCFM (300 L/min ANR)
Fluid Admitted: Air
Min. Pressure Range at 21ºC: 21.8 psi (0.15 MPa)
Proof Pressure: 218 psi (1.5 MPa)
Service Pressure Range at 20ºC: 0~150 psi (0~1MPa)
Service Temperature Range: 41~140ºF (5~60ºC)
Type test: Mist Filter w/ Manual Drain
Bowl Capacity: 1 US oz. (30cc)
Filtration Rating: 0.3 micrometer
Flow Rate: 10.6 SCFM (300 L/min ANR)
Fluid Admitted: Air
Min. Pressure Range at 21ºC: 7.3 psi (0.05 MPa)
Proof Pressure: 218 psi (1.5 MPa)
Service Pressure Range at 20ºC: 0~150 psi (0~1MPa)
Service Temperature Range: 41~140ºF (5~60ºC)
Type test: Model with Regulator
Flow Rate: 10.6 SCFM (300 L/min ANR)
Fluid Admitted: Air
Gauge Accuracy: +/- 5% of full span
Gauge Pressure Range: 0~145 psi (0~1MPa)
Pressure Setting Range: 7.2~123.3 psi (0.05~0.85MPa)
Proof Pressure: 174 psi (1.2 MPa)
Service Pressure Range at 20ºC: 0~150 psi (0~1MPa)
Service Temperature Range: 41~140ºF (5~60ºC)