Complex Vacuum Generator with Blow-off Air and Relief Pressure Adjustment. More control in vacuum release air than our VG
- Pressure adjusting function is added to the conventional blow-off air control function to prevent work-pieces from being blown away
- A relief mechanism built into the blow-off circuit which breaks the vacuum (extra pressure is relieved) realizes shorter blow-off time
Specifications
Type test: VZE07
Air Consumption at 73 psi (50 psi for E): 0.60 SCFM (17 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.37 SCFM (10.5 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)
Type test: VJE10
Air Consumption at 73 psi (50 psi for E): 1.19 SCFM (34 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.74 SCFM (21 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)
Type test: VJE12
Air Consumption at 73 psi (50 psi for E): 1.65 SCFM (47 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.95 SCFM (27 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)
Type test: VJH05
Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.25 SCFM (7 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)
Type test: VJH07
Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.46 SCFM (13 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93.1 kPa)
Type test: VJH10
Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.95 SCFM (27 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93.1 kPa)
Type test: VJH12
Air Consumption at 73 psi (50 psi for E): 2.45 SCFM (70 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 1.33 SCFM (38 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93.1 kPa)
Type test: VJL05
Air Consumption at 73 psi (50 psi for E): 0.49 SCFM (11.5 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.39 SCFM (11 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)
Type test: VJL07
Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.91 SCFM (26 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)
Type test: VJL10
Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 1.4 SCFM (40 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)
Type test: VJP
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)