Sensor head is measured 24.5 x 10 x 10 mm and comes with union fitting, plug-in stem or male thread.
- Switch output or analog output in positive pressure range, negative pressure range, or compound pressure range sensor make 6 different types of out put specifications are available
- Standard cable length is 3 meters
- 31.4 x 31.4 mm square remote LED display works with analog output type sensor
Specifications
Type test: Indicator SED-30
Analog Output: 1~5 VDC +/- 0.1V
Analog Output Current: 1 mA max.
Display Units: kPa, kgf/cm2, gf/cm2, mmHg, mmH20, bar, mbar, psi, kpsi, MPa, in.Hg
Hysteresis (Switch Output): Fixed to 1% of F.S.
Linearity: +/- 0.5% of full span
Operating Accuracy: +/- 1% of full span
Operating Humidity Range: 35~85%RH
Output Type: 2 switches
Power Consumption: 50 mA max.
Power Supply: 10.8~30VDC
Protective Structure: IEC IP40
Service Temperature Range: 32~122ÂşF (0~50ÂşC)
Switch Output Type: 30V 100mA NPN
Type test: SEU11
Analog Output: 1~5 VDC +/- 0.1V
Analog Output Current: 1 mA max.
Fluid Admitted: Air, Inert Gas
Hysteresis (Switch Output): Fixed to 2% of F.S.
Linearity: +/- 0.5% of full span
Operating Accuracy: +/- 3% of full span
Operating Humidity Range: 35~85%RH
Output Type: 1 switch or 1 analog
Power Consumption: 20 mA or less
Power Supply: 10.8~30VDC
Pressure Setting Range: 0~150 psi (0~1MPa)
Proof Pressure: 218 psi (1.5MPa)
Protective Structure: IEC IP40
Service Pressure Range at 20ÂşC: 0~150 psi (0~1MPa)
Service Temperature Range: 32~140ÂşF (0~60ÂşC)
Switch Output Type: 30V 80mA NPN
Type test: VUS11
Analog Output: 1~5 VDC +/- 0.1V
Analog Output Current: 1 mA max.
Fluid Admitted: Air, Inert Gas
Hysteresis (Switch Output): Fixed to 2% of F.S.
Linearity: +/- 0.5% of full span
Operating Accuracy: +/- 3% of full span
Operating Humidity Range: 35~85%RH
Output Type: 1 switch or 1 analog
Power Consumption: 20 mA or less
Power Supply: 10.8~30VDC
Pressure Setting Range: 0~-30 in.Hg (0~-100 kPa)
Proof Pressure: 29 psi (200 kPa)
Protective Structure: IEC IP40
Service Pressure Range at 20ÂşC: 0~-30 in.Hg (0~-100 kPa)
Service Temperature Range: 32~140ÂşF (0~60ÂşC)
Switch Output Type: 30V 80mA NPN
Type test: VUS11-R
Analog Output: 1~5 VDC +/- 0.1V
Analog Output Current: 1 mA max.
Fluid Admitted: Air, Inert Gas
Hysteresis (Switch Output): Fixed to 2% of F.S.
Linearity: +/- 0.5% of full span
Operating Accuracy: +/- 3% of full span
Operating Humidity Range: 35~85%RH
Output Type: 1 switch or 1 analog
Power Consumption: 20 mA or less
Power Supply: 10.8~30VDC
Pressure Setting Range: -30~89in.Hg (-100~300 kPa)
Proof Pressure: 87 psi (600 kPa)
Protective Structure: IEC IP40
Service Pressure Range at 20ÂşC: -30~89in.Hg (-100~300 kPa)
Service Temperature Range: 32~140ÂşF (0~60ÂşC)
Switch Output Type: 30V 80mA NPN