The Dry Unit is a combination of Fiber Dry Filter, Micro Mist Filter and Regulator.
- No electric power supply is required. Air Filter, Mist Filter (Micromist Filter) and Regulator are integrated
- Space-saving type achieving direct connection to air source
Specifications
Type test: Model Code 301
Ambient Temperature Range: 32~131ºF (0~55ºC)
Bowl Capacity: 1 US oz. (30cc)
Filtration Rating: Filter: 5 micrometer, Mist Filter: 0.3 micrometer, Micromist Filter: 0.01 micrometer
Flow Rate: 3.52 SCFM (100 L/min ANR)
Fluid Admitted: Air
Fluid Temperature Range: 32~131ºF (0~55ºC)
Gauge Accuracy: +/- 5% of full span
Gauge Pressure Range: 0~145 psi (0~1MPa)
Inside Membrane Max. Pressure Range at 20ºC: 43.5~123.3 psi (0.3~0.85 psi)
Outside Membrane Max. Pressure Range at 20ºC: 0~7.3 psi (0~0.05 psi)
Pressure Setting Range: 7.2~123.3 psi (0.05~0.85MPa)
Type test: Model Code 500
Ambient Temperature Range: 32~131ºF (0~55ºC)
Bowl Capacity: 1 US oz. (30cc)
Filtration Rating: Filter: Filter: 5 micrometer, Mist Filter: 0.3 micrometer, Micromist Filter: 0.02 micrometer
Flow Rate: 10.6 SCFM (300 L/min ANR)
Fluid Admitted: Air
Fluid Temperature Range: 32~131ºF (0~55ºC)
Gauge Accuracy: +/- 5% of full span
Gauge Pressure Range: 0~145 psi (0~1MPa)
Inside Membrane Max. Pressure Range at 20ºC: 43.5~123.3 psi (0.3~0.85 psi)
Outside Membrane Max. Pressure Range at 20ºC: 0~7.3 psi (0~0.05 psi)
Pressure Setting Range: 7.2~123.3 psi (0.05~0.85MPa)