By adopting the hollow fiber to the filter, the filtration accuracy of 0.01µm and, trapping efficiency of 99.99% has been realized.
- Filtering Accuracy: 0.01ƒÊm, Correcting Efficiency: 99.99%
- Small Body, Lightweight and Large Flow Rate
- Explosion-proof structure by a plastic body covering the filter case
- Oil-Free, Stainless Steel and Cleanroom Package as standard specification.
Specifications
Type test: MFU100-1010
Filtering Accuracy: 0.01µm(Trapping efficiency: 99.99%)
Fluid Medium: Air, Nitrogen
Max Operating Flow: Min. 100L/min[ANR]
Max Operating Pressure at 20ºC: 145psi (1.0MPa)
Membrane Area: 215cm2
Operating Temperature Range: 41~122ºF (5~50ºC)
Proof Differential Pressure: 36psi (0.25MPa)
Proof Pressure: 218psi (1.5MPa)
Remarks: With a blast shelter Oil-impervious specification
Type test: MFU100-66
Filtering Accuracy: 0.01µm(Trapping efficiency: 99.99%)
Fluid Medium: Air, Nitrogen
Max Operating Flow: Min. 100L/min[ANR]
Max Operating Pressure at 20ºC: 145psi (1.0MPa)
Membrane Area: 215cm2
Operating Temperature Range: 41~122ºF (5~50ºC)
Proof Differential Pressure: 36psi (0.25MPa)
Proof Pressure: 218psi (1.5MPa)
Remarks: With a blast shelter Oil-impervious specification
Type test: MFU100-88
Filtering Accuracy: 0.01µm(Trapping efficiency: 99.99%)
Fluid Medium: Air, Nitrogen
Max Operating Flow: Min. 100L/min[ANR]
Max Operating Pressure at 20ºC: 145psi (1.0MPa)
Membrane Area: 215cm2
Operating Temperature Range: 41~122ºF (5~50ºC)
Proof Differential Pressure: 36psi (0.25MPa)
Proof Pressure: 218psi (1.5MPa)
Remarks: With a blast shelter Oil-impervious specification
Type test: MFU50-44
Filtering Accuracy: 0.01µm(Trapping efficiency: 99.99%)
Fluid Medium: Air, Nitrogen
Max Operating Flow: Min. 50L/min[ANR]
Max Operating Pressure at 20ºC: 145psi (1.0MPa)
Membrane Area: 107cm2
Operating Temperature Range: 41~122ºF (5~50ºC)
Proof Differential Pressure: 36psi (0.25MPa)
Proof Pressure: 218psi (1.5MPa)
Remarks: With a blast shelter Oil-impervious specification
Type test: MFU50-66
Filtering Accuracy: 0.01µm(Trapping efficiency: 99.99%)
Fluid Medium: Air, Nitrogen
Max Operating Flow: Min. 50L/min[ANR]
Max Operating Pressure at 20ºC: 145psi (1.0MPa)
Membrane Area: 107cm2
Operating Temperature Range: 41~122ºF (5~50ºC)
Proof Differential Pressure: 36psi (0.25MPa)
Proof Pressure: 218psi (1.5MPa)
Remarks: With a blast shelter Oil-impervious specification
Type test: MFU50-88
Filtering Accuracy: 0.01µm(Trapping efficiency: 99.99%)
Fluid Medium: Air, Nitrogen
Max Operating Flow: Min. 50L/min[ANR]
Max Operating Pressure at 20ºC: 145psi (1.0MPa)
Membrane Area: 107cm2
Operating Temperature Range: 41~122ºF (5~50ºC)
Proof Differential Pressure: 36psi (0.25MPa)
Proof Pressure: 218psi (1.5MPa)
Remarks: With a blast shelter Oil-impervious specification