• 100% Satisfaction
    Guaranteed
  • Request for Quote

    We offer volume discounts!

VACUUM GENERATORS (MULTI-TASK / MANIFOLD SOLENOID)

Vacuum Generators (Multi-Task / Manifold Solenoid)
  • Vacuum Generators VG

    Basic stand alone type multi-functional vacuum generator.

    • Vacuum switch and blow-off valve are united. Select the best combination in accordance with applications
    • There are 3 output types: 1 switch output and 1 analog output type, 2-point switch output type, and cost saving 1 analog output type

    Specifications

    Type test: E07
    Air Consumption at 73 psi (50 psi for E): 0.60 SCFM (17 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.37 SCFM (10 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.8 in.Hg (-90 kPa)

    Type test: E10
    Air Consumption at 73 psi (50 psi for E): 1.19 SCFM (34 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.74 SCFM (21 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.8 in.Hg (-90 kPa)

    Type test: H05
    Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.25 SCFM (7 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.8 in.Hg (-90 kPa)

    Type test: H07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.46 SCFM (13 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.6 in.Hg (-93 kPa)

    Type test:  H10
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.95 SCFM (27 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.6 in.Hg (-93 kPa)

    Type test: L05
    Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.42 SCFM (12 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    Type test: L07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.91 SCFM (26 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    Type test: L10
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 1.4 SCFM (40 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    ...
    Read More
  • Vacuum Generators VJ

    Complex Vacuum Generator with Blow-off Air and Relief Pressure Adjustment. More control in vacuum release air than our VG

    • Pressure adjusting function is added to the conventional blow-off air control function to prevent work-pieces from being blown away
    • A relief mechanism built into the blow-off circuit which breaks the vacuum (extra pressure is relieved) realizes shorter blow-off time

    Specifications

    Type test: VZE07
    Air Consumption at 73 psi (50 psi for E): 0.60 SCFM (17 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.37 SCFM (10.5 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)

    Type test: VJE10
    Air Consumption at 73 psi (50 psi for E): 1.19 SCFM (34 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.74 SCFM (21 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)

    Type test: VJE12
    Air Consumption at 73 psi (50 psi for E): 1.65 SCFM (47 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.95 SCFM (27 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)

    Type test: VJH05
    Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.25 SCFM (7 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)

    Type test: VJH07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.46 SCFM (13 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93.1 kPa)

    Type test: VJH10
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.95 SCFM (27 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93.1 kPa)

    Type test: VJH12
    Air Consumption at 73 psi (50 psi for E): 2.45 SCFM (70 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 1.33 SCFM (38 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93.1 kPa)

    Type test: VJL05
    Air Consumption at 73 psi (50 psi for E): 0.49 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.39 SCFM (11 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)

    Type test: VJL07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.91 SCFM (26 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)

    Type test: VJL10
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 1.4 SCFM (40 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)

    Type test: VJP
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)

    ...
    Read More
  • Vacuum Generators VK

    18 different combinations of multi-functional vacuum generators which are also available as manifolds.

    • Vacuum Generator can be used in various combinations with built-in check valve, vacuum switch, vacuum breadking valve, etc., or their units to suit your applications
    • The vacuum switch offers a selection between the high-performance electronic type and the low-cost, easy-to-use mechanical type
    • The vacuum breaking valve, which allows you to choose from the solenoid valve type and the air timer type, incorporates a special change-over valve, thus enabling quick breaking of vacuum or air blowing
    • Multiple vacuum generators can be formed into a manifold, and each of them can be set to a different capacity

    Specifications

    Type test: E07
    Air Consumption at 73 psi (50 psi for E): 0.60 SCFM (17 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.37 SCFM (10 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.9 in.Hg (-91 kPa)

    Type test: E10
    Air Consumption at 73 psi (50 psi for E): 1.19 SCFM (34 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.74 SCFM (21 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.9 in.Hg (-91 kPa)

    Type test: E12
    Air Consumption at 73 psi (50 psi for E): 1.65 SCFM (47 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.95 SCFM (27 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.9 in.Hg (-91 kPa)

    Type test: H05
    Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.25 SCFM (7 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.9 in.Hg (-91 kPa)

    Type test: H07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.46 SCFM (13 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93 kPa)

    Type test: H10
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.95 SCFM (27 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93 kPa)

    Type test: H12
    Air Consumption at 73 psi (50 psi for E): 2.47 SCFM (70 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 1.33 SCFM (38 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93 kPa)

    Type test: L05
    Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.39 SCFM (11 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.8 in.Hg (-67 kPa)

    Type test: L07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.91 SCFM (26 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.8 in.Hg (-67 kPa)

    Type test: L10
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 1.4 SCFM (40 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.8 in.Hg (-67 kPa)

    Type test: L12
    Air Consumption at 73 psi (50 psi for E): 2.47 SCFM (70 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 1.75 SCFM (50 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.8 in.Hg (-67 kPa)

    ...
    Read More
  • Vacuum Generators VN

    Space-saving Vacuum Generator best suitable for high-speed and stable response

    • Suitable for semiconductor industry such as IC chip loader or IC handler
    • Suitable for the application requiring a limited space
    ...
    Read More
  • Vacuum Generators VQ

    Largest suction flow multi-functional vacuum generator unit in the PISCO line-up.

    • 31.5-mm wide vacuum unit is designed to optimize the control of large vacuum flows
    • Three different types of vacuum generator are available: single-nozzle type (nozzle bore: 1.5mm, 2.0mm), two-stage nozzle type (nozzle bore: 0.7mm, 1.0mm, 1.2mm) and twin-nozzle type.
    ...
    Read More
  • Vacuum Generators VX

    10mm width multi-functional vacuum generator is available as a stand alone or manifold.

    • Lightweight and compact body meeting market needs
    • Pursue of faster responsiveness of suction solenoid valve to the extreme realized the high cycle of vacuum system
    • Wide variety of combinations enables to meet various applications. External Vacuum Controller for vacuum pump is also available
    • 2 installation methods are selectable. Direct-installation type is to fix the product from side using threads. The other DIN rail type is to install the product on DIN rail. Selection according to the application is possible
    • Vacuum switch with visibility improved LED display, and one with analog output with reasonable price are selectable

    Specifications

    Type test: VXE07
    Air Consumption at 73 psi (50 psi for E): 0.60 SCFM (17 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.37 SCFM (10.5 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)

    Type test: VXE10-J
    Air Consumption at 73 psi (50 psi for E): 1.19 SCFM (34 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.67 SCFM (19 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)

    Type test: VXE10-S
    Air Consumption at 73 psi (50 psi for E): 1.19 SCFM (34 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.71 SCFM (20 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)

    Type test: VXH05
    Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.25 SCFM (7 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)

    Type test: VXH07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.46 SCFM (13 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93.1 kPa)

    Type test: VXH10-J
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.71 SCFM (20 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93.1 kPa)

    Type test: VXH10-S
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.85 SCFM (24 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93.1 kPa)

    Type test: VXL05
    Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.42 SCFM (12 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)

    Type test: VXL07-J
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.78 SCFM (22 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)

    Type test: VXL07-S
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.85 SCFM (24 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)

    Type test: VXL10-S
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.91 SCFM (26 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)

    Type test: VXP
    Fluid Admitted: Vacuum
    Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
    Power Supply: 24VDC / 100VAC
    Service Pressure Range at 20ºC: 0~-29 in.Hg (0~-100 kPa)
    Service Temperature Range: 41~122ºF (5~50ºC)

    ...
    Read More
  • Vacuum Generators VZ

    Manifold-mounted 10mm width multi-functional vacuum generator is available with modular wirings

    • Compact manifold type with lightweight body
    • Large volume of blow-off air by air pressure release valve which have achieved to reduce blow-off time
    • Bundled wiring of the suction and blow-off solenoid valves

    Specifications

    Type test: VZE07
    Air Consumption at 73 psi (50 psi for E): 0.60 SCFM (17 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 0.55W
    Power Supply: 24VDC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.37 SCFM (10.5 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)

    Type test: VZE10
    Air Consumption at 73 psi (50 psi for E): 1.19 SCFM (34 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 0.55W
    Power Supply: 24VDC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.71 SCFM (20 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)

    Type test: VZH05
    Air Consumption at 73 psi (50 psi for E): 0.41 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 0.55W
    Power Supply: 24VDC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.25 SCFM (7 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)

    Type test: VZH07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 0.55W
    Power Supply: 24VDC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.46 SCFM (13 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93.1 kPa)

    Type test: VZH10
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 0.55W
    Power Supply: 24VDC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.85 SCFM (24 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93.1 kPa)

    Type test: VZL05
    Air Consumption at 73 psi (50 psi for E): 0.41 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 0.55W
    Power Supply: 24VDC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.42 SCFM (12 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)

    Type test: VZL07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Power Consumption: 0.55W
    Power Supply: 24VDC
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
    Service Temperature Range: 41~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 0.85 SCFM (24 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)

    Type test: VZP
    Fluid Admitted: Vacuum
    Power Consumption: 0.55W
    Power Supply: 24VDC
    Service Pressure Range at 20ºC: 0~-29 in.Hg (0~-100 kPa)
    Service Temperature Range: 41~122ºF (5~50ºC)

    ...
    Read More
×