18 different combinations of multi-functional vacuum generators which are also available as manifolds.
- Vacuum Generator can be used in various combinations with built-in check valve, vacuum switch, vacuum breadking valve, etc., or their units to suit your applications
- The vacuum switch offers a selection between the high-performance electronic type and the low-cost, easy-to-use mechanical type
- The vacuum breaking valve, which allows you to choose from the solenoid valve type and the air timer type, incorporates a special change-over valve, thus enabling quick breaking of vacuum or air blowing
- Multiple vacuum generators can be formed into a manifold, and each of them can be set to a different capacity
Specifications
Type test: E07
Air Consumption at 73 psi (50 psi for E): 0.60 SCFM (17 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.37 SCFM (10 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -26.9 in.Hg (-91 kPa)
Type test: E10
Air Consumption at 73 psi (50 psi for E): 1.19 SCFM (34 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.74 SCFM (21 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -26.9 in.Hg (-91 kPa)
Type test: E12
Air Consumption at 73 psi (50 psi for E): 1.65 SCFM (47 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.95 SCFM (27 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -26.9 in.Hg (-91 kPa)
Type test: H05
Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.25 SCFM (7 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -26.9 in.Hg (-91 kPa)
Type test: H07
Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.46 SCFM (13 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93 kPa)
Type test: H10
Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.95 SCFM (27 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93 kPa)
Type test: H12
Air Consumption at 73 psi (50 psi for E): 2.47 SCFM (70 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 1.33 SCFM (38 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93 kPa)
Type test: L05
Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.39 SCFM (11 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.8 in.Hg (-67 kPa)
Type test: L07
Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.91 SCFM (26 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.8 in.Hg (-67 kPa)
Type test: L10
Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 1.4 SCFM (40 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.8 in.Hg (-67 kPa)
Type test: L12
Air Consumption at 73 psi (50 psi for E): 2.47 SCFM (70 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 0.8W / 100VAC: 1VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 36.3~102 psi (0.25~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 1.75 SCFM (50 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.8 in.Hg (-67 kPa)