Direct mountable on PISCO vacuum pad or pad holder.
- Nozzle size: 16 types
- VC, VM Type (Vacuum pad Direct Mounting)
- Light-weight and compact design (Main body of large VC models with taper thread are made of aluminum)
- Low profile VC, VM Type is ideal for applications with space and weight restriction
Specifications
Type test: E07
Air Consumption at 73 psi (50 psi for E): 0.60 SCFM (17 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 0.36 SCFM (10 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -26.8 in.Hg (-90 kPa)
Type test: E10
Air Consumption at 73 psi (50 psi for E): 1.19 SCFM (34 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 0.74 SCFM (21 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)
Type test: E12
Air Consumption at 73 psi (50 psi for E): 1.65 SCFM (47 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 0.95 SCFM (27 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)
Type test: E15
Air Consumption at 73 psi (50 psi for E): 2.47 SCFM (70 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 1.48 SCFM (42 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)
Type test: E20
Air Consumption at 73 psi (50 psi for E): 5.30 SCFM (150 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 2.94 SCFM (84 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)
Type test: H05
Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 0.25 SCFM (7 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -26.8 in.Hg (-90 kPa)
Type test: H07
Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 0.45 SCFM (13 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)
Type test: H10
Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 0.99 SCFM (28 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.6 in.Hg (-93 kPa)
Type test: H12
Air Consumption at 73 psi (50 psi for E): 2.47 SCFM (70 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 1.34 SCFM (38 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.6 in.Hg (-93 kPa)
Type test: H15
Air Consumption at 73 psi (50 psi for E): 3.5 SCFM (100 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 2.22 SCFM (63 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.6 in.Hg (-93 kPa)
Type test: H20
Air Consumption at 73 psi (50 psi for E): 7.06 SCFM (200 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 3.85 SCFM (110 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.6 in.Hg (-93 kPa)
Type test: L05
Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 0.39 SCFM (11 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)
Type test: L07
Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 0.9 SCFM (24 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)
Type test: L10
Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 1.48 SCFM (42 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)
Type test: L15
Air Consumption at 73 psi (50 psi for E): 3.5 SCFM (100 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 3.35 SCFM (95 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)
Type test: L20
Air Consumption at 73 psi (50 psi for E): 7.06 SCFM (200 L/min ANR)
Fluid Admitted: Air
Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
Service Temperature Range: 32~140ºF (0~60ºC)
Suction Flow at 73 psi (50 psi for E): 6.3 scfm (180 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)