• 100% Satisfaction
    Guaranteed
  • Request for Quote

    We offer volume discounts!

VACUUM GENERATORS (STAND ALONE)

Vacuum Generators (Stand Alone)
  • Material Handling Vacuum VYR

    A vacuum generator with multiple vacuum ports for direct mounting on a robotic arm.

    • The Cylinder with built-in Vacuum Generator self-retracts and lifts the object immediately after making contact with the object via compressed air supply
    • Various selection of pad sizes, materials and cylinder storkes
    ...
    Read More
  • Vacuum Cylinders

    The vacuum cylinder is a vacuum pad incorporating a vacuum generator and cylinder. Let compressed air flow, and your work will be held and raised under suction.

    • Pad dia.: 4~40 mm (0.16~1.57 in.)
    • Pad material: Nitrile rubber, Silicon rubber, Fluorosilicon rubber
    • Stroke: 5~30 mm (0.2~1.18 in.)

    Specifications

    Type test: VSPE
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.3~102 psi (0.15~0.7 Mpa)
    Suction Flow at 73 psi (50 psi for E): 0.27SCFM (7.6 L/min.ANR)
    Vacuum Level at 73 psi (50 psi for E): -27 in.Hg (-91 kPa)

    ...
    Read More
  • Vacuum Generators VB

    Box shaped union type vacuum generators with/without mechanical vacuum switch: VUSM.

    • Nozzle size: 10 types
    • Compact plastic body, Light weight

    Specifications

    Type test: E07
    Air Consumption at 73 psi (50 psi for E): 0.60 SCFM (17 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.36 SCFM (10 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.8 in.Hg (-90 kPa)

    Type test: E10
    Air Consumption at 73 psi (50 psi for E): 1.19 SCFM (34 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.74 SCFM (21 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)

    Type test: E12
    Air Consumption at 73 psi (50 psi for E): 1.65 SCFM (47 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.95 SCFM (27 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)

    Type test: H05
    Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.25 SCFM (7 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.8 in.Hg (-90 kPa)

    Type test: H07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.45 SCFM (13 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)

    Type test: H10
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.99 SCFM (28 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.6 in.Hg (-93 kPa)

    Type test: H12
    Air Consumption at 73 psi (50 psi for E): 2.47 SCFM (70 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 1.34 SCFM (38 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.6 in.Hg (-93 kPa)

    Type test: L05
    Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.42 SCFM (12 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    Type test: L07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.91 SCFM (26 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    Type test: L10
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 1.48 SCFM (42 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    ...
    Read More
  • Vacuum Generators VC/VM

    Direct mountable on PISCO vacuum pad or pad holder.

    • Nozzle size: 16 types
    • VC, VM Type (Vacuum pad Direct Mounting)
    • Light-weight and compact design (Main body of large VC models with taper thread are made of aluminum)
    • Low profile VC, VM Type is ideal for applications with space and weight restriction

    Specifications

    Type test: E07
    Air Consumption at 73 psi (50 psi for E): 0.60 SCFM (17 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.36 SCFM (10 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.8 in.Hg (-90 kPa)

    Type test: E10
    Air Consumption at 73 psi (50 psi for E): 1.19 SCFM (34 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.74 SCFM (21 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)

    Type test: E12
    Air Consumption at 73 psi (50 psi for E): 1.65 SCFM (47 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.95 SCFM (27 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)

    Type test: E15
    Air Consumption at 73 psi (50 psi for E): 2.47 SCFM (70 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 1.48 SCFM (42 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)

    Type test: E20
    Air Consumption at 73 psi (50 psi for E): 5.30 SCFM (150 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 2.94 SCFM (84 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)

    Type test: H05
    Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.25 SCFM (7 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.8 in.Hg (-90 kPa)

    Type test: H07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.45 SCFM (13 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)

    Type test: H10
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.99 SCFM (28 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.6 in.Hg (-93 kPa)

    Type test: H12
    Air Consumption at 73 psi (50 psi for E): 2.47 SCFM (70 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 1.34 SCFM (38 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.6 in.Hg (-93 kPa)

    Type test: H15
    Air Consumption at 73 psi (50 psi for E): 3.5 SCFM (100 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 2.22 SCFM (63 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.6 in.Hg (-93 kPa)

    Type test: H20
    Air Consumption at 73 psi (50 psi for E): 7.06 SCFM (200 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 3.85 SCFM (110 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.6 in.Hg (-93 kPa)

    Type test: L05
    Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.39 SCFM (11 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    Type test: L07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.9 SCFM (24 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    Type test: L10
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 1.48 SCFM (42 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    Type test: L15
    Air Consumption at 73 psi (50 psi for E): 3.5 SCFM (100 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 3.35 SCFM (95 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    Type test: L20
    Air Consumption at 73 psi (50 psi for E): 7.06 SCFM (200 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 6.3 scfm (180 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    ...
    Read More
  • Vacuum Generators VH / VS

    Direct mountable on solenoid valve with threaded ports.

    • Valve Direct Mounting Type
    • Nozzle size: 13 types

    Specifications

    Type test: E07
    Air Consumption at 73 psi (50 psi for E): 0.60 SCFM (17 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.36 SCFM (10 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.8 in.Hg (-90 kPa)

    Type test: E10
    Air Consumption at 73 psi (50 psi for E): 1.19 SCFM (34 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.74 SCFM (21 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)

    Type test: E12
    Air Consumption at 73 psi (50 psi for E): 1.65 SCFM (47 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.95 SCFM (27 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)

    Type test: E15
    Air Consumption at 73 psi (50 psi for E): 2.47 SCFM (70 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 1.48 SCFM (42 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)

    Type test: H05
    Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.25 SCFM (7 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.8 in.Hg (-90 kPa)

    Type test: H07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.45 SCFM (13 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)

    Type test: H10
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.99 SCFM (28 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.6 in.Hg (-93 kPa)

    Type test: H12
    Air Consumption at 73 psi (50 psi for E): 2.47 SCFM (70 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 1.34 SCFM (38 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.6 in.Hg (-93 kPa)

    Type test: H15
    Air Consumption at 73 psi (50 psi for E): 3.5 SCFM (100 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 2.22 SCFM (63 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.6 in.Hg (-93 kPa)

    Type test: L05
    Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.42 SCFM (12 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    Type test: L07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.9 SCFM (24 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    Type test: L10
    Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 1.48 SCFM (42 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    Type test: L15
    Air Consumption at 73 psi (50 psi for E): 3.5 SCFM (100 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 3.35 SCFM (95 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    ...
    Read More
  • Vacuum Generators VLM

    The large flow vacuum generator VLM provides high vacuum and flow rates. It features a multi-stage nozzle and multi layer structure for suction flow approx. 2.2 times (on average) larger than air consumption. Silencer installation is selectable from three directions.

    • Multi stage nozzle ejector ensuring high vacuum of 27.8 inHg (-94kPa)
    • Excellent in ozone resistance
    • Silencer installing direction is selectable
    • Body can be fixed freely with two brackets
    • Suitable for applications in various industrial fields

    Specifications

    Type test: 161
    Air Consumption (/min ANR): 110L (3.9cfm)
    Fluid Medium: Air
    Layers: Single Layer
    Nozzle Diameter (mm): 1.6
    Nozzle Quantity: 1 pc.
    Operating Pressure Range (MPa): 0.3 - 0.7 (43.5 - 101.5psi)
    Operating Temp. Range (ºC): 5 -50 (no freezing) (41 - 122ºF)
    Rated Supply Pressure (MPa): 0.5 (72.5psi)
    Suction Flow Rate (/min ANR): 290L (10.2cfm)

    Type test: 162
    Air Consumption (/min ANR): 220L (7.8cfm)
    Fluid Medium: Air
    Layers: Single Layer
    Nozzle Diameter (mm): 1.6
    Nozzle Quantity: 2 pcs
    Operating Pressure Range (MPa): 0.3 - 0.7 (43.5 - 101.5psi)
    Operating Temp. Range (ºC): 5 -50 (no freezing) (41 - 122ºF)
    Rated Supply Pressure (MPa): 0.5 (72.5psi)
    Suction Flow Rate (/min ANR): 550L (19.4cfm)

    Type test: 163
    Air Consumption (/min ANR): 330L (11.7cfm)
    Fluid Medium: Air
    Layers: Double Layer
    Nozzle Diameter (mm): 1.6
    Nozzle Quantity: 3 pcs
    Operating Pressure Range (MPa): 0.3 - 0.7 (43.5 - 101.5psi)
    Operating Temp. Range (ºC): 5 -50 (no freezing) (41 - 122ºF)
    Rated Supply Pressure (MPa): 0.5 (72.5psi)
    Suction Flow Rate (/min ANR): 760L (26.8cfm)

    Type test: 164
    Air Consumption (/min ANR): 440L (15.5cfm)
    Fluid Medium: Air
    Layers: Double Layer
    Nozzle Diameter (mm): 1.6
    Nozzle Quantity: 4 pcs
    Operating Pressure Range (MPa): 0.3 - 0.7 (43.5 - 101.5psi)
    Operating Temp. Range (ºC): 5 -50 (no freezing) (41 - 122ºF)
    Rated Supply Pressure (MPa): 0.5 (72.5psi)
    Suction Flow Rate (/min ANR): 890L (31.4cfm)

    Type test: 165
    Air Consumption (/min ANR): 550L (19.4cfm)
    Fluid Medium: Air
    Layers: Triple Layer
    Nozzle Diameter (mm): 1.6
    Nozzle Quantity: 5 pcs
    Operating Pressure Range (MPa): 0.3 - 0.7 (43.5 - 101.5psi)
    Operating Temp. Range (ºC): 5 -50 (no freezing) (41 - 122ºF)
    Rated Supply Pressure (MPa): 0.5 (72.5psi)
    Suction Flow Rate (/min ANR): 1,020L (36.0cfm)

    Type test: 166
    Air Consumption (/min ANR): 660L (23.3cfm)
    Fluid Medium: Air
    Layers: Triple Layer
    Nozzle Diameter (mm): 1.6
    Nozzle Quantity: 6 pcs
    Operating Pressure Range (MPa): 0.3 - 0.7 (43.5 - 101.5psi)
    Operating Temp. Range (ºC): 5 -50 (no freezing) (41 - 122ºF)
    Rated Supply Pressure (MPa): 0.5 (72.5psi)
    Suction Flow Rate (/min ANR): 1,110L (39.2cfm)

    ...
    Read More
  • Vacuum Generators VRL

    Ejector for conveying particles, powder and fibers

    • To convey small, irregular materials, such as particles, powder and fibers in the air current
    • The suction port and the exhaust port are located in a straight line. The works sucked in from the suction port pass through the inside of the vacuum generator and go out of the exhaust port. Thus the vacuum generator enables conveyance of works through a tube.

    Specifications

    Type test: VRL100
    Air Consumption at 73 psi (50 psi for E): 3.5 SCFM (100 L/min ANR)
    Fluid Admitted: Air
    Max. Diameter Conveyable: 0.14 in. (3.6 mm)
    Service Pressure Range at 20ºC: 0~150 psi (0~1MPa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 3.5 SCFM (100 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -15.6 in.Hg (-53 kPa)

    Type test: VRL200
    Air Consumption at 73 psi (50 psi for E): 7.0 SCFM (200 L/min ANR)
    Fluid Admitted: Air
    Max. Diameter Conveyable: 0.21 in. (5.5 mm)
    Service Pressure Range at 20ºC: 0~150 psi (0~1MPa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 7.0 SCFM (200 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -15.6 in.Hg (-53 kPa)

    Type test: VRL300
    Air Consumption at 73 psi (50 psi for E): 10.6 SCFM (300 L/min ANR)
    Fluid Admitted: Air
    Max. Diameter Conveyable: 0.27 in. (7 mm)
    Service Pressure Range at 20ºC: 0~150 psi (0~1MPa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 10.6 SCFM (300 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)

    Type test: VRL50
    Air Consumption at 73 psi (50 psi for E): 1.8 SCFM (50 L/min ANR)
    Fluid Admitted: Air
    Max. Diameter Conveyable: 0.09 in. (2.3 mm)
    Service Pressure Range at 20ºC: 0~150 psi (0~1MPa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 1.8 SCFM (50 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -15.6 in.Hg (-53 kPa)

    ...
    Read More
  • Vacuum Generators VU / VUM

    Union type vacuum generators with quick fitting. Air powered venturi vacuum can be used in combination with a vacuum pad to handle materials.

    • VU in line vacuum generator coming with a plastic body is very lightweight and compact
    • Nozzle bore selection : ø0.5 and ø0.7mm
    • Nozzle size: 6 types

    Specifications

    Type test: E07
    Air Consumption at 73 psi (50 psi for E): 0.60 SCFM (17 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.36 SCFM (10 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.8 in.Hg (-90 kPa)

    Type test: H05
    Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.25 SCFM (7 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.8 in.Hg (-90 kPa) 

    Type test: H07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.45 SCFM (13 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.2 in.Hg (-92 kPa)

    Type test: L05
    Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.42 SCFM (12 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    Type test: L07
    Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
    Fluid Admitted: Air
    Service Pressure Range at 20ºC: 21.8~102 psi (0.15~0.7 Mpa)
    Service Temperature Range: 32~140ºF (0~60ºC)
    Suction Flow at 73 psi (50 psi for E): 0.9 SCFM (24 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -19.7 in.Hg (-66 kPa)

    ...
    Read More
  • Vacuum Generators VVV

    Multi-stage nozzle high vacuum ejector at low air pressure supply.

    • Ensuring high vacuum pressure & high vacuum flow by low 50psi air supply
    • Long life cycle and easy maintenance
    • Vacuum ports direction can be changed
    • Straight or elbow silencer is available depending upon the installing space
    • Digital pressure gauge is available as an option
    • Best suitable for a large & heavy workpiece in industries such as packaging or automobile, or suitable for an air-permeable workpiece

    Specifications

    Type test: E16
    Air Consumption at 73 psi (50 psi for E): 3.7 CFM (105 L/min ANR)
    Fluid Fluid Admitted: Air
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 MPa)
    Service Temperature Range: 40~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 6.3 CFM (180 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -26.6 in.Hg (-90 kPa)

    Type test: E25
    Air Consumption at 73 psi (50 psi for E): 9.5 CFM (270 L/min ANR)
    Fluid Fluid Admitted: Air
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 MPa)
    Service Temperature Range: 40~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 15.0 CFM (430 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.8 in.Hg (-94 kPa)

    Type test: E27
    Air Consumption at 73 psi (50 psi for E): 9.5 CFM (270 L/min ANR)
    Fluid Fluid Admitted: Air
    Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 MPa)
    Service Temperature Range: 40~122ºF (5~50ºC)
    Suction Flow at 73 psi (50 psi for E): 17.5 CFM (500 L/min ANR)
    Vacuum Level at 73 psi (50 psi for E): -27.8 in.Hg (-94 kPa)

    ...
    Read More
  • Vacuum Generators VY

    Vacuum Generator with blow-off function

    • Ejector and Blow-Off Mechanism are integrated. VY Type provides a high cost performance, compared to a normal solenoid valve equipped type
    • Small and lightweight body makes it possible to place on the terminal part of the vacuum piping. High speed cycle of suction and Blow-Off Mechanism is achieved by diffuser spool
    • VU vacuum generator coming with a plastic body is very lightweight and compact

    Specifications

    Fluid Medium: Air
    Lubrication: Not required
    Operating Pressure Range: 43.5~102 psi (0.3~0.7MPa)
    Operating Temperature Range: 41~122ºF (5~50ºC)

    ...
    Read More
×