10mm width multi-functional vacuum generator is available as a stand alone or manifold.
- Lightweight and compact body meeting market needs
- Pursue of faster responsiveness of suction solenoid valve to the extreme realized the high cycle of vacuum system
- Wide variety of combinations enables to meet various applications. External Vacuum Controller for vacuum pump is also available
- 2 installation methods are selectable. Direct-installation type is to fix the product from side using threads. The other DIN rail type is to install the product on DIN rail. Selection according to the application is possible
- Vacuum switch with visibility improved LED display, and one with analog output with reasonable price are selectable
Specifications
Type test: VXE07
Air Consumption at 73 psi (50 psi for E): 0.60 SCFM (17 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.37 SCFM (10.5 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)
Type test: VXE10-J
Air Consumption at 73 psi (50 psi for E): 1.19 SCFM (34 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.67 SCFM (19 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)
Type test: VXE10-S
Air Consumption at 73 psi (50 psi for E): 1.19 SCFM (34 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.71 SCFM (20 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)
Type test: VXH05
Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.25 SCFM (7 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -26.7 in.Hg (-90.4 kPa)
Type test: VXH07
Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.46 SCFM (13 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93.1 kPa)
Type test: VXH10-J
Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.71 SCFM (20 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93.1 kPa)
Type test: VXH10-S
Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.85 SCFM (24 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -27.5 in.Hg (-93.1 kPa)
Type test: VXL05
Air Consumption at 73 psi (50 psi for E): 0.40 SCFM (11.5 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.42 SCFM (12 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)
Type test: VXL07-J
Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.78 SCFM (22 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)
Type test: VXL07-S
Air Consumption at 73 psi (50 psi for E): 0.81 SCFM (23 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.85 SCFM (24 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)
Type test: VXL10-S
Air Consumption at 73 psi (50 psi for E): 1.61 SCFM (46 L/min ANR)
Fluid Admitted: Air
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 43.5~102 psi (0.3~0.7 Mpa)
Service Temperature Range: 41~122ºF (5~50ºC)
Suction Flow at 73 psi (50 psi for E): 0.91 SCFM (26 L/min ANR)
Vacuum Level at 73 psi (50 psi for E): -19.6 in.Hg (-66.5 kPa)
Type test: VXP
Fluid Admitted: Vacuum
Power Consumption: 24VDC: 1.2W / 100VAC: 1.5VA
Power Supply: 24VDC / 100VAC
Service Pressure Range at 20ºC: 0~-29 in.Hg (0~-100 kPa)